CS106/BL106 Combined Door Entry and Coded Access
22
Programming the Lock Duration (Function 95)
This is the duration the lock release will operate for when triggered by an access
code or by the ‘EXIT’ input. It is programmable in the range 1-99 seconds.
Procedure
Enter the current Security
key (default 1212).
Type :
95
+
++
+
<1-99> #
Both LEDs flash once
Exit program mode by
pressing
++
++++
++
Factory Setting = 3 seconds
Example
95
+
++
+
7 #
(7 seconds)
95
+
++
+
12 #
(12 seconds)