46
Bell res
English
Instructions for use and installation instructions
5 FAULTS
Possible reasons for the gas fi re going out are:
The concentric fl ue system is not installed according to one of the methods detailed
in Paragraph 3.4
An incorrect “fl ue gas restriction plate” is fi tted.
The pilot light extinguishes if fumes are not exhausted or are insuffi ciently
exhausted.
The pilot light is either dirty or defective.
Insuffi cient gas pressure.
Thermocouple voltage is too low. This is usually caused by insuffi cient heating of
the thermocouple by the pilot light.
Dirty electrical contacts in the thermo-electrical system; for example, the
thermocouple connection.
Batteries in receiver or remote control are fl at.