Bell System bell free Spécifications Page 33

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 44
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 32
BF Apartment Station 1 Way System
PD-167 Issue 1C Installation and Operating Manual Page 33 of 44
Diagram D – 1 Way Multiple Entrance Wiring Overview
Lock
release
Lock
release
2 x
1mm²
BFD1 1 way
Door Controller
BFD1 1 way
Door Controller
Up to
50m
2x
Cat5
2x
Cat5
(Options) (Options)
Lock wiring options
Lock 0.5A 1.0A
12m 1 pair 1 pair
25m 1 pair 2 pair
50m 2 pair 4 pair
50m 2x1mm² 2x1mm²
All cable MUST be
4 pair data cable.
Except for power
wiring where stated.
Cat5
150m Max
(1 Apartment station)
(For over 150m or
extensions
see diagrams F&G)
Cat5
Cat5Cat5
Entrance Options
Exit button 1 pair
Door monitor 1 pair
Trades 1pair
Further
Entrances
Entrance 2 Entrance 1
BF
Apartment
Station
PSU
PS4
12V
2 x
1mm²
3m
Max
230V
Mains
Vue de la page 32